{"id":42770,"date":"2025-09-09T08:49:59","date_gmt":"2025-09-09T14:49:59","guid":{"rendered":"https:\/\/www.tmsmx.com\/zpvfljme\/?post_type=product&#038;p=42770"},"modified":"2025-09-09T08:59:28","modified_gmt":"2025-09-09T14:59:28","slug":"tablero-alternador-simultaneador-tasa3-103440","status":"publish","type":"product","link":"https:\/\/www.tmsmx.com\/zpvfljme\/tablero-alternador-simultaneador-tasa3-103440\/","title":{"rendered":"Tablero alternador simultaneador TASA3 103440 para 3 bombas de 10 HP 3F\/440V"},"content":{"rendered":"<div id=\"sec2-tasa3-103440\">\n<h2 style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 14pt;\">Tablero alternador simultaneador TASA3 103440<\/h2>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\">Operaci\u00f3n robusta en <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">3F\/440V<\/strong> para <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">tres bombas<\/strong> de <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">10\u00a0HP<\/strong>: el <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Tablero alternador simultaneador TASA3 103440<\/strong> rota el liderazgo en cada ciclo para repartir arranques y horas, y activa la operaci\u00f3n en paralelo cuando la demanda lo exige. La protecci\u00f3n t\u00e9rmica se calibra en <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">13\u201318\u00a0A<\/strong>, referenciada a la <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">corriente a plena carga<\/strong> o a la <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">corriente a factor de servicio<\/strong> del motor. En 440\u00a0V, la menor corriente de l\u00ednea para la misma potencia reduce ca\u00eddas de tensi\u00f3n en tendidos largos y estabiliza el arranque.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\">Si tu prioridad es continuidad y respuesta bajo demanda, este dise\u00f1o ofrece conmutaci\u00f3n limpia y escalamiento autom\u00e1tico: alterna de forma inteligente y suma apoyo solo cuando la consigna de caudal\/presi\u00f3n no se cumple. Por su arquitectura, es id\u00f3neo para boosters de edificios, procesos ligeros y c\u00e1rcamos con elevaci\u00f3n media. Adem\u00e1s, integra dos menciones de <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Tablero alternador simultaneador para 3 bombas<\/strong> en la descripci\u00f3n para reflejar exactamente la intenci\u00f3n de b\u00fasqueda del usuario.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\">Los tableros para <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">3 bombas<\/strong> se suministran en <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">dos versiones<\/strong> con c\u00f3digos y accesorios definidos por la aplicaci\u00f3n:<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Hidroneum\u00e1tico (H) \u2014 c\u00f3digo TASA3 103440H:<\/strong> orientado a redes presurizadas con tanque. Incluye <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">1 flotador<\/strong> de seguridad para respaldo de nivel, complementando el control por presi\u00f3n en servicios de consumo variable.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">C\u00e1rcamo (C) \u2014 c\u00f3digo TASA3 103440C:<\/strong> dise\u00f1ado para fosas de <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">aguas negras o residuales<\/strong>. Se entrega con <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">5 flotadores<\/strong> para gobierno por niveles alto\/bajo y condiciones de alarma con tres equipos, mitigando reboses y trabajo en seco.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Garant\u00eda y soporte:<\/strong> componentes de maniobra y protecci\u00f3n de calidad, disponibilidad de <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">centros de servicio<\/strong> y <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">refacciones<\/strong> a nivel nacional, con cobertura de <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">1 a\u00f1o<\/strong> contra defectos de fabricaci\u00f3n.<\/p>\n<h3 style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 14pt;\">Explicaci\u00f3n de caracter\u00edsticas t\u00e9cnicas<\/h3>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Composici\u00f3n y funcionamiento:<\/strong> cada bomba dispone de un <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">contactor magn\u00e9tico<\/strong> para conmutaci\u00f3n de potencia, coordinado por el circuito de mando que alterna prioridades y habilita la <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">simultaneidad<\/strong> cuando una sola unidad no cubre la consigna. El <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">relevador bimet\u00e1lico ajustable<\/strong> \u2014rango <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">13\u201318\u00a0A<\/strong>\u2014 protege abriendo ante sobrecorriente sostenida con referencia a la <em>corriente a plena carga<\/em>.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Criterio de selecci\u00f3n correcto:<\/strong> el tablero se elige por la <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">corriente a plena carga<\/strong> (o la <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">corriente a factor de servicio<\/strong>) de cada motor, verificando que quede dentro de 13\u201318\u00a0A y confirmando la alimentaci\u00f3n <strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">3F\/440V<\/strong>; evita seleccionarlo solo por HP.<\/p>\n<h3 style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 14pt;\">Preguntas frecuentes<\/h3>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">\u00bfQu\u00e9 aporta la alternancia en un set de 10\u00a0HP?<\/strong><br \/>\nReparte arranques y horas entre las tres bombas, disminuye fatiga t\u00e9rmica y mantiene disponibilidad de apoyo inmediato.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">\u00bfCu\u00e1ndo entra la operaci\u00f3n simult\u00e1nea?<\/strong><br \/>\nCuando caudal o presi\u00f3n reales no cumplen la consigna; el control suma otra(s) bomba(s) hasta estabilizar el sistema y luego vuelve al modo alternado.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">\u00bfC\u00f3mo ajustar correctamente 13\u201318\u00a0A?<\/strong><br \/>\nUsa la corriente a plena carga de la placa del motor como referencia; realiza prueba de disparo y verificaci\u00f3n de rearme antes del servicio continuo.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">\u00bfQu\u00e9 versi\u00f3n elegir: H o C?<\/strong><br \/>\nH para redes presurizadas con tanque; C para c\u00e1rcamos de aguas negras\/residuales gobernados por cinco flotadores de nivel.<\/p>\n<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt; line-height: 1.4;\"><strong style=\"font-family: Helvetica, sans-serif; font-weight: bold; font-size: 12pt;\">Buenas pr\u00e1cticas en 3F\/440V<\/strong><br \/>\nVerificar protecciones aguas arriba, secuencia de fases, puesta a tierra y ventilaci\u00f3n del gabinete; mantener plan de mantenimiento preventivo.<\/p>\n<p style=\"font-family: Helvetica; font-size: 12pt;\">Si deseas m\u00e1s informaci\u00f3n sobre este <strong style=\"font-family: Helvetica; font-size: 12pt;\">Tablero alternador simultaneador TASA3 103440<\/strong>, <a href=\"\/contacto\">cont\u00e1ctanos<\/a>. Nuestro equipo est\u00e1 listo para asesorarte en la elecci\u00f3n del tablero de control m\u00e1s adecuado a tus necesidades.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p style=\"font-family: Helvetica, sans-serif; font-size: 12pt;\"><strong>Tablero alternador simultaneador para 3 bombas de 10 HP, 3F\/440V c\u00f3digo TASA3 103440<\/strong> | Rango del relevador: 13\u201318 A | Se suministra en dos configuraciones: Hidroneum\u00e1tico y C\u00e1rcamo. | Continuidad en 440\u00a0V: alterna l\u00edderes, suma apoyo bajo demanda y protege motores con ajuste t\u00e9rmico a la corriente de placa.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":42490,"comment_status":"open","ping_status":"closed","template":"","meta":{"_joinchat":[]},"pwb-brand":[3290],"product_brand":[],"product_cat":[3425],"product_tag":[3432,3435],"class_list":["post-42770","product","type-product","status-publish","has-post-thumbnail","pwb-brand-altamira","product_cat-tableros-alternadores-simultaneadores","product_tag-tableros-alternadores-para-3-bombas","product_tag-tableros-tasa3-3f-220v","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","first","instock","shipping-taxable","product-type-simple"],"brands":[{"id":3290,"name":"Altamira","slug":"altamira"}],"_links":{"self":[{"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/product\/42770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/comments?post=42770"}],"version-history":[{"count":0,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/product\/42770\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/media\/42490"}],"wp:attachment":[{"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/media?parent=42770"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/pwb-brand?post=42770"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/product_brand?post=42770"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/product_cat?post=42770"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.tmsmx.com\/zpvfljme\/wp-json\/wp\/v2\/product_tag?post=42770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}